The Effect of Charcoal on the Improvement of Grounding Resistance as a Soil Treatment in Reducing Grounding Resistance
Abstract
Current technological developments are very competitive with each other, both in electric power distribution systems or electronic equipment. Disturbances that occur are usually caused by short circuits and ground disturbances, or lightning strikes. These disturbances will result in a voltage drop or increase in voltage, which results in decreased system stability, endangers people's lives, and can damage electronic equipment. Coconut Shell Charcoal has a lower resistivity value than soil and has a larger pore structure to absorb more water, and has conductive properties. The results obtained from the comparison using dry coconut shell charcoal and wet coconut shell charcoal show that measurements using wet coconut shell charcoal are better (less resistance) than using dry coconut shell charcoal. Soil resistivity measurements will be much better at the maximum depth than the usual depth (110 cm), better than 10cm.
Keywords
Full Text:
PDFReferences
A. Syakur. (2008). Comparative Analysis of Grounding Resistance Value in Soil and Septic tank, TEKNIK, vol. 29, no. 3, pp. 203–208.
TS Hutahuruk. 1991. Neutral grounding of power systems and grounding equipment, Second. Jakarta: Erlangga.
BSN. (2000). General Requirements for Electrical Installations 2000 (PUIL 2000), vol. 2000, no. PUIL.2000, p. 562.
Earthing Techniques, “Soil Resistivity Testing,” pp. 1– 40.
GS Pambayun, RYE Yulianto, M. Rachimoellah, and EMM Putri. (2013) Making activated carbon from coconut shell charcoal using activators ZnCl2 and Na 2CO3 as adsorbents to reduce phenol levels in wastewater. J. Tek. POMITS, vol. 2, no. 1, pp. 116–120.
Herman and W. Joetra. (2015). The effect of table salt (NaCl) on the shrinkage of clay. J. Momentum, vol. 17, no. 1, pp. 13–20.
WP Widyaningsih et al. (2017). Decreasing Earthing Resistance by Using. vol. 13, no. 3, pp. 102–106.
Sudaryanto. (2016). Comparative Analysis of Earthly Resistance Value in Wet Soil, Sandy Soil and Field Soil. J. Electr. Technol. Vol. 1, No. 1, February 2016, vol. 1, no. 1.
J. Uddin and S. Sumarno. (2017). Planning an Integrated Electric Power Grounding System in Buildings. J. Electr. Electron. Eng., Vol. 1, no. 1, p. 29, DOI: 10.21070 / jeee-u.v1i1.375.
M. Mukmin, A. Kali, and B. Mukhlis. (2014). Comparison of the Value of Grounding Resistance in Coastal Reclamation Areas (CITRALAND). J. MEKTRIK, vol. 1, no. 1, pp. 29–39.
E. Yuniarti. (2016). "Gypsum as Soil Treatment in Reducing Grounding Prisoners in Fields," Jurnal.Umj.Ac.Id/Index.Php/Semnastek, no. November, pp. 1–7.
M. Rajagukguk. (2012). Study of Effect of Soil Types and Grounding Depth of Driven Rod on Soil Type Resistance. Jur. Tech. Electrical, Fac. Tech. Univ. Tanjungpura.
DOI: https://doi.org/10.29103/jreece.v1i1.3619
Article Metrics
Abstract Views : 513 timesPDF Downloaded : 105 times
Refbacks
- There are currently no refbacks.
Copyright (c) 2021 Partaoanan Harahap Partaoanan Harahap
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.