Root Cause Analysis of Electrical Faults in Industry & other Facility

Authors

  • Md Shameem Ahsan Active Power Engineering & Consultancy
  • Md Khaledur Rahman NIPRO JMI Company Ltd
  • Manam Ahmed Active Power Engineering & Consultancy
  • Faysal Amin Tanvir Maintenance Officer (Electrical), SMC Enterprise Ltd
  • Md Saiful Islam Multi System Engineering Company Ltd

DOI:

https://doi.org/10.29103/jreece.v4i2.14854

Keywords:

Electrical Fault, Fire Safety, Risk Analysis, Sustainability, Short-Circuit

Abstract

The sole purpose of this analysis was to discuss the broader picture of fire incidents that occurred in industry due to electrical faults. Nowadays, fire incidents in industries as well as in residential and commercial buildings are a common case. Local and international print & electronic media report fire incidents every day. The fatalities are remarkable and also caused extensive property damage, and undoubtedly, it can be mitigated upon consideration of a few factors. This article identifies the exact causes of electrical faults, investigating previous fire incident reports in various industries and other possible reasons. During the past decades, there has been a noticeable change in infrastructure and industrial development worldwide. Because of land shortage and improper planning, the number of high-rise buildings in the industry sector increases without maintaining electrical standards, increasing fire incidents, fatality rates, and substantial property damages. Though strong laws, national and international standards, and regulatory measures existed, accidents occurred regularly. Also, there is no significant guideline for electrical product quality, run time, and materials selection, which plays a major role in fire incidents. This report anticipates understanding the lack in the existing system, considerable findings for installations, and extending to further studies to find out proper remediation.

References

Campbell, R. (April 2018) Report: Nfpa's "Fires In U.S. Industrial Or Manufacturing Properties"

Svare, M. J., Hanke, N. W. & Daeid, N. N., (2023) Forensic Examination Of Post-Fire Damaged Electrical Conductors By

Quantitative Measurement Doi: 10.51501/Jotnafe.V40i1.856

Https://Hyundai-Electric.Es/Media/Images/Catalogos/Pi-Interruptor-Caja-Moldeada-Hgp-Mccb-Eng.Pdf, Page-48

(Accessed Date: September 27, 2023)

Bangladesh National Building Code- Bnbc- 2020, Electrical Part

Vytenis, B. (2001) "How Do Electrical Wiring Faults Lead To Structure Ignitions", Proc. Fire And Materials 2001 Conf.

Xin, Z. & Schoepf, T. (2011) "Characteristics Of Overheated Electrical Joints Due To Loose Connection", 2011 Ieee 57th Holm

Conference On Electrical Contacts (Holm), Doi: 10.1109/Holm.2011.6034795

Lewand, L. R. & Koehler, D. (2003) The Science Of Sampling Insulating Liquids. Powertest Conference, The Premier

Electrical Maintenance And Safety Event.

Gray, I. A. R. (2009) A Guide To Transformer Oil Analysis. Transformer Chemistry Service

El-Harbawi, M & Al-Mubaddel, F. (2020) Risk Of Fire And Explosion In Electrical Substations Due To The Formation Of

Flammable Mixtures Doi: 10.1038/S41598-020-63354-4

Https://Lima.Dife.Gov.Bd/Public-Report/Factory-Profile (Accessed Date: February 10, 2023)

Hamrick, L. (2010) Dissolved Gas Analysis For Transformers Neta World (International Engineering Testing

Association, 2010).

Aronstein, J. (2022) Faulty Residential Circuit Breakers - A Persistent Fire Safety Problem Eee Open Journal Of

Industry Applications. Doi 10.1109/Ojia.2023.3237956

Gajić, Z., BrnÄić, I., Hillström, B. & Ivanković, I. (2005) Sensitive Turn-To-Turn Fault Protection For Power Transformers In

Joint Meetings Of Cigré Study Committee B5 And Ieee Power System Relaying Committee, With The Study

Committee B5 Colloquium.

Https://Internationalaccord.Org/Factories/ (Accessed Date: June 15, 2023)

Kumar, K.S. S. & Kalappan, K. B. (2023) Fire Risks In Electrical Installations: The Review

Yang, F., Cai, Z., Su, L., Xue, Y., Chen, X., Shen, Y. & Wang, J. (2022) Research On Online Monitoring And Cause

Identification System Of Building Electrical Fire

Chen, H., Han, C., Zhang, Y., Ma, Z., Zhang, H. & Yuan, Z. (2023) Investigation On The Fault Monitoring Of High-Voltage

Circuit Breaker Using Improved Deep Learning

Wang, L., Li, D. & Guo, C. (2023) Technical Appraisal Method Of Circuit Breaker Material Evidence In Fire

Sato, T., Hayashi, Y., Mizuki, T., Et Al. (2020) ˜Simulation-Based Analysis Of Inductance At Loose Connector Contact

Boundaries. The 27th Int. Conf. On Electrical Contacts, Dresden, Germany, 2014, Pp. 1-4

Gore, P. K. & Gore, P (2018) Failure Due To Poor Termination & Loose Connections In Electrical Systems

Bach Aj, Stewart Ib, Disher Ae, Costello Jt (2015) A Comparison Between Conductive And Infrared Devices For Meas-

Uring Mean Skin Temperature At Rest, During Exercise In The Heat, And Recovery.

J. Wang, Z.-J. Shu, Z. Chen, The Protective Effect Of A Fire-Retardant Coating On The Insulation Failure Of Pvc Cable, Eng.

Fail. Anal. 34 (2013) 1-9, Http://Dx.Doi.Org/ 10.1016/J.Engfailanal.2013.07.010

Pham, K. D. & Jones, R. (2009) Arc Flash Hazard Analysis In Traction Power Substations Asme Joint Rail Conference.

Doi:10.1115/Jrc2009-63038

The Business Standard (2022, November 26) Electrical Short-Circuits Causes About 40% Fire Incidents: Fire Service

(Retrieved)

Wen Xishan, W. & Peng, D. (2005) Effects Of Water Trees On Insulation Resistance And Dc Component Of Xlpe Cable.

Engineering Journal Of Wuhan University, 2005, 38(3):112-115.

Roybal, D.D., (2004)Circuit Breaker Interrupting Capacity And Short-Time Current Ratings. [Ieee Conference Record Of

Annual Pulp And Paper Industry Technical Conference - Victoria, Bc, Canada (27 June-1 July 2004)] (0),

-134 Doi:10.1109/Papcon.2004.1338373

Vij K. (2011) Textbook Of Forensic Medicine And Toxicology. 5th Ed. India. Elsevier. 2011;175-82.

Tyagi A, Shankar S, Chawla H, Yadav K, Kumar H., (2019) High Voltage Electrocution Injury - A Case Report. Int J

Forensic Med Toxicol Sci. 2019; 4: 68-70.

Https://Fireservice.Portal.Gov.Bd/Site/Files/E4d115ed-D51b-4bfc-B941-2092c1a5c916/ (Accessed Date: July 17, 2023)

Janic, Z., Gavrilov, N., Roketinec, I. (2023) Influence Of Cooling Management To Transformer Efficiency And Ageing

Energies 2023, 16, 4626, Doi: 10.3390/En16124626s

Downloads

Published

09-10-2024